Catechin_5.0×10-5M + Cyanidin 3-glucoside_1.5×10-5M
Machine: Hitachi Hi-tech F-7000Date: 2025/8/9
Sample: Catechin_5.0×10-5M and Cyanidin 3-glucoside_1.5×10-5M in water
PMT: 600V
Excitation wavelength interval: 5nm
Emission wavelength interval: 5nm
Scan speed: 30,000nm/min
Ex Slit: 5nm
Em Slit: 5nm
Measured by: Mako Fujikawa
Download data
Catechin_5.0×10-5M + Cyanidin 3-glucoside_3.0×10-5M
Machine: Hitachi Hi-tech F-7000Date: 2025/8/9
Sample: Catechin_5.0×10-5M and Cyanidin 3-glucoside_3.0×10-5M in water
PMT: 600V
Excitation wavelength interval: 5nm
Emission wavelength interval: 5nm
Scan speed: 30,000nm/min
Ex Slit: 5nm
Em Slit: 5nm
Measured by: Mako Fujikawa
Download data
Catechin_5.0×10-5M + Cyanidin 3-glucoside_5.0×10-5M
Machine: Hitachi Hi-tech F-7000Date: 2025/8/9
Sample: Catechin_5.0×10-5M and Cyanidin 3-glucoside_5.0×10-5M in water
PMT: 600V
Excitation wavelength interval: 5nm
Emission wavelength interval: 5nm
Scan speed: 30,000nm/min
Ex Slit: 5nm
Em Slit: 5nm
Measured by: Mako Fujikawa
Download data
Catechin_5.0×10-5M + Cyanidin 3-glucoside_1.0×10-4M
Machine: Hitachi Hi-tech F-7000Date: 2025/8/9
Sample: Catechin_5.0×10-5M and Cyanidin 3-glucoside_1.0×10-4M in water
PMT: 600V
Excitation wavelength interval: 5nm
Emission wavelength interval: 5nm
Scan speed: 30,000nm/min
Ex Slit: 5nm
Em Slit: 5nm
Measured by: Mako Fujikawa
Download data
Catechin_5.0×10-5M + Resveratrol_1.0×10-5M
Machine: Hitachi Hi-tech F-7000Date: 2025/8/9
Sample: Catechin_5.0×10-5M and Resveratrol_1.0×10-5M in water
PMT: 600V
Excitation wavelength interval: 5nm
Emission wavelength interval: 5nm
Scan speed: 30,000nm/min
Ex Slit: 5nm
Em Slit: 5nm
Measured by: Mako Fujikawa
Download data
Catechin_5.0×10-5M + Resveratrol_2.0×10-5M
Machine: Hitachi Hi-tech F-7000Date: 2025/8/9
Sample: Catechin_5.0×10-5M and Resveratrol_2.0×10-5M in water
PMT: 600V
Excitation wavelength interval: 5nm
Emission wavelength interval: 5nm
Scan speed: 30,000nm/min
Ex Slit: 5nm
Em Slit: 5nm
Measured by: Mako Fujikawa
Download data
Catechin_5.0×10-5M + Resveratrol_4.0×10-5M
Machine: Hitachi Hi-tech F-7000Date: 2025/8/9
Sample: Catechin_5.0×10-5M and Resveratrol_4.0×10-5M in water
PMT: 600V
Excitation wavelength interval: 5nm
Emission wavelength interval: 5nm
Scan speed: 30,000nm/min
Ex Slit: 5nm
Em Slit: 5nm
Measured by: Mako Fujikawa
Download data
Catechin_5.0×10-5M + Resveratrol_6.5×10-5M
Machine: Hitachi Hi-tech F-7000Date: 2025/8/9
Sample: Catechin_5.0×10-5M and Resveratrol_6.5×10-5M in water
PMT: 600V
Excitation wavelength interval: 5nm
Emission wavelength interval: 5nm
Scan speed: 30,000nm/min
Ex Slit: 5nm
Em Slit: 5nm
Measured by: Mako Fujikawa
Download data
Epicatechin 5μg/mL
Machine: Hitachi Hi-tech F-7000Date: 2025/4/10
Sample: Epicatechin 5μg/mL (1.72×10-5M) in 70% ethanol
PMT: 700V
Excitation wavelength interval: 5nm
Emission wavelength interval: 5nm
Scan speed: 30,000nm/min
Ex Slit: 5nm
Em Slit: 5nm
Measured by: Shusuke Yui
Download data
Epicatechin 5μg/mL + Caffeine 20μg/mL
Machine: Hitachi Hi-tech F-7000Date: 2025/4/10
Sample: Epicatechin 5μg/mL (1.72×10-5M) and Caffeine 20μg/mL (1.03×10-4M) in 70% ethanol
PMT: 700V
Excitation wavelength interval: 5nm
Emission wavelength interval: 5nm
Scan speed: 30,000nm/min
Ex Slit: 5nm
Em Slit: 5nm
Measured by: Shusuke Yui
Download data
Epicatechin 5μg/mL + Caffeine 20μg/mL + Quercetine 20μg/mL
Machine: Hitachi Hi-tech F-7000Date: 2025/4/10
Sample: Epicatechin 5μg/mL (1.72×10-5M), Caffeine 20μg/mL (1.03×10-4M), and Quercetine 20μg/mL (0.66×10-4M) in 70% ethanol
PMT: 700V
Excitation wavelength interval: 5nm
Emission wavelength interval: 5nm
Scan speed: 30,000nm/min
Ex Slit: 5nm
Em Slit: 5nm
Measured by: Shusuke Yui
Download data
Epicatechin 10μg/mL
Machine: Hitachi Hi-tech F-7000Date: 2025/4/10
Sample: Epicatechin 10μg/mL (3.44×10-5M) in 70% ethanol
PMT: 700V
Excitation wavelength interval: 5nm
Emission wavelength interval: 5nm
Scan speed: 30,000nm/min
Ex Slit: 5nm
Em Slit: 5nm
Measured by: Shusuke Yui
Download data
Epicatechin 10μg/mL + Caffeine 50μg/mL
Machine: Hitachi Hi-tech F-7000Date: 2025/4/10
Sample: Epicatechin 10μg/mL (3.44×10-5M) and Caffeine 50μg/mL (2.58×10-4M)in 70% ethanol
PMT: 700V
Excitation wavelength interval: 5nm
Emission wavelength interval: 5nm
Scan speed: 30,000nm/min
Ex Slit: 5nm
Em Slit: 5nm
Measured by: Shusuke Yui